Practices adopted by nursing professionals for indirect measurement and recording of blood pressure
DOI:
https://doi.org/10.5935/1415-2762.20170005Keywords:
Hypertension, Blood Pressure Measurement, Nursing, Nursing RecordsAbstract
The aim of this study was to identify how the procedure for indirect measurement and recording of blood pressure by nursing professionals is
performed and the technical conditions of the devices used. It is a quantitative, observational, cross-sectional study. The sample consisted of 80
servers, observed from August 2013 to January 2014, in five health units in Londrina, Paraná. In the data collection, it was used as a reference to
measure an instrument made from the steps described in the VI Brazilian Guidelines on Hypertension and, for the record of the proceeding, a tool
built according to the recommendations of the COREn, São Paulo. For data analysis, we used the Program Statistical Package for Social Science
version 1.6. The results showed high rates of "non-performance" (93.8% to 100%) of the steps for preparing the patient for measurement of pressure.
The calibration of the equipment is not measured, and there are not cuffs of varied sizes. It is concluded that there are important gaps related to
the practice adopted by nurses to measure blood pressure, indicating the need for implementation of educational measures.
Downloads
References
World Health Organization. Global action plan for the prevention and control of noncommunicable diseases.2013-2020.Geneve: WHO; 2013. [citado em 2013 dez. 02]. Disponível em: http://www.who.int/nmh/events/2013/revised_draft_ncd_action_plan.pdf
World Health Organization. Global health risks: mortality and burden of disease attributable to selected major risks. Geneve: WHO; 2009. [citado em 2013 dez. 02]. Disponível em: http://www.who.int/healthinfo/global_burden_disease/GlobalHealthRisks_report_full.pdf
World Heart Federation. Hypertension and cardiovascular disease. [citado em 2014 abr. 08]. Disponível em:http://www.world-heart-federation.org/cardiovascular-health/cardiovascular-disease-risk-factors/hypertension/
Sociedade Brasileira de Cardiologia. VI Diretrizes brasileiras de hipertensão arterial. São Paulo: SBC; 2010. [citado em 2013 dez. 02]. Disponível em: http://publicacoes.cardiol.br/consenso/2010/Diretriz_hipertensao_associados.pdf
Center for Disease Control and Prevention. Atlanta. Chronic disease indicators. [citado em 2014 maio 02]. Disponível em:http://apps.nccd.cdc.gov/cdi/
Nobre F. Valores de pressão arterial para o diagnóstico e metas: análise crítica das diretrizes mais recentes. Rev Soc Cardiol. 2015[citado em 2015 dez 30];4(1):19-22. Disponível em: http://www.socesp.org.br/upload/revista/2015/REVISTA-SOCESP-V25-N1.pdf
Dieterle T. Blood pressure measurement - an- overview. Swiss Med Weekly. 2012[citado em 2014 maio 04];142:1-9. Disponível em: http://www.smw.ch/content/smw-2012-13517/
Gusmão JL, Raymundo AC, Campos CL, Mano GP, Alencar NP, Silva JS, et alFontes de erro na medida da pressão arterial: papel do esfigmomanômetro e do observador. Rev Hipertensão. 2011[citado em 2014 maio 04];14(2):33-44. Disponível em: http://www.sbh.org.br/pdf/2012_2.pdf
Alsanjari ON, Lusignan S, van Vlymen J, Gallagher H, Millett C, Harris K, et alTrends and transient change in end-digit preference in blood pressure recording: studies of sequential and longitudinal collected primary care data. Int J ClinPract. 2012[citado em 2014 maio 10];66(1):37-43. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/22171903
Mouro DL. Medida indireta e registro da pressão arterial: práticas adotadas por profissionais de enfermagem [dissertação]. Ribeirão Preto: Universidade de São Paulo, Escola de Enfermagem de Ribeirão Preto; 2014. [citado em 2015 out. 06]. Disponível em: http://www.teses.usp.br/teses/disponiveis/22/22132/tde-06022015-200608/
Ministério da Saúde (BR). Banco de dados do Sistema Único de Saúde-DATASUS, Cadastro Nacional de Estabelecimentos de Atenção à Saúde - CNES. [citado em 2013 jan. 21]. Disponível em: http://cnes.datasus.gov.br/Lista_Es_Municipio.asp?VEstado=41&VCodMunicipio=411370&NomeEstado=PARANA
Conselho Regional de Enfermagem. Anotações de Enfermagem. 2009. [citado em 2014 fev. 12]. Disponível em: http://www.portaldaenfermagem.com.br/downloads/manual-anotacoes-de-enfermagem-coren-sp.pdf
Tognoli SH. Medida indireta da pressão arterial: avaliação de programa de educação permanente oferecido em dispositivo móvel[dissertação] Riberão Preto: Escola de Enfermagem de Ribeirão Preto; 2012. 101 f.
Wisconsin Heart Disease and Stroke Prevention Program. Division of Public Health. Department of Health Services. Blood pressure measurement toolkit: improving accuracy, enhancing care. Madison; 2010. [citado em 2014 jan. 20]. Disponível em: http://www.dhs.wisconsin.gov/publications/p0/p00623.pdf
Parte 3: III Diretrizes Brasileiras de Monitorização Residencial da Pressão Arterial (MRPA). Arq Bras Cardiol. 2011[citado em 2016 maio 08];97(3):17-24. Disponível em: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2011001800004&lng=en
Almeida TCF, Lamas JLT. Enfermeiros de Unidade de Terapia Intensiva adulto: avaliação sobre medida direta e indireta da pressão arterial. Rev Esc Enferm USP. 2013[citado em 2014 maio 08];47(2):369-76. Disponível em: http://www.scielo.br/pdf/reeusp/v47n2/14.pdf
Boll LFC, Irigoyen MC, Goldmeier S. Diretrizes brasileiras de hipertensão arterial: realidade da enfermagem em hospital especializado. Acta Paul Enferm. 2012[citado em 2014 maio 08]; 25(5):775-80. Disponível em: http://www.scielo.br/pdf/ape/v25n5/20.pdf
Alavarce DC, Pierin AMG. Elaboração de uma hipermídia educacional para o ensino do procedimento de medida da pressão arterial. Rev Esc Enferm USP. 2011[citado em 2014 maio 08];45(4):939-44. Disponível em: http://www.scielo.br/pdf/reeusp/v45n4/v45n4a21.pdf
Freestone S, Ramsay LE. Effect of coffee and cigarette smoking on the blood pressure of untreated and diuretic-treated hypertensive patients. Am J Med. 1982.[citado em 2014 maio 10];73(3):348-53. Disponível em: http://www.ncbi.nlm.nih.gov/pubmed/7124761
Arcuri EAM. Fatores de erro na medida da pressão arterial: a influência do manguito. Rev Hipertens. 2011[citado em 2014 maio 12];14(2):21-32. Disponível em: http://www.sbh.org.br/pdf/2012_2.pdf
Nietert PJ, Wessell AM, Feifer C, Ornstein SM. Effect of terminal digit preference on blood pressure measurement and treatment in primary care. Am J Hypertens. 2006[citado em 2014 maio 12];19(2):147-52. http://www.ncbi.nlm.nih.gov/pubmed/16448884
Conselho Regional de Enfermagem. Anotações de Enfermagem. São Paulo: COREN SP; 2009. [citado em 2016 abr. 20]. Disponível em: http://www.sobecc.org.br/programacao/coren/anotacoes_enfermagem.pdf
Conselho Regional de Enfermagem. Decisão COREN-SP-DIR/001/2000. Normatiza no Estado de São Paulo os princípios gerais para ações que constituem a documentação de Enfermagem. São Paulo: COREN SP; 2000. [citado em 2014 fev. 08]. Disponível em: http://portal.coren-sp.gov.br/node/30747
Freitas CCQ, Pantarotto RFR, Costa LRLG. Relação circunferência braquial e tamanho de manguitos utilizados nas Unidades Básicas de Saúde de uma cidade do interior paulista. J Health Sci. 2013[citado em 2014 maio 10];31(3):48-52. http://www.unip.br/comunicacao/publicacoes/ics/edicoes/2013/01_jan-mar/V31_n1_2013_p48a52.pdf
Published
Issue
Section
License
Copyright (c) 2017 Reme: Revista Mineira de Enfermagem

This work is licensed under a Creative Commons Attribution 4.0 International License.