Automatic evaluation of sprinkler irrigation systems/ Avaliação automática de sistemas de irrigação por aspersão convencional
Palavras-chave:
CUC. Water-use efficiency. Agricultural automation.CUC. Água-uso eficiente. Automação agrícola.Resumo
One of the problems of irrigation is the high demand of water. On occasion, water supply may not be available, or even with availability, water should be preserved. Allied to this, the lack of monitoring and proper management of systems may provide low uniformity and low efficiency irrigation. This study aims to develop and test a device that can evaluate irrigation systems having as parameters the mean depth and coefficient of uniformity application in an automatized and easy way. Sensors were tested to take readings of water level. The sensor set was built with catch cans, so it was able to collect data for system evaluation. The obtained data were compared with those obtained by measuring the volume in the catch cans with the aid of a beaker. Data were submitted to statistical tests for comparison of means. The device was suitable for use under field conditions showing better results with larger irrigation depths. The microcontroller was easy to program and handling with results broadly supportive systematic evaluation of the irrigation system.
RESUMO
Um dos problemas da irrigação é a alta demanda d’água, sendo que em certas ocasiões esta não está tão disponível, ou até mesmo em condições com disponibilidade ela deve ser preservada. Aliado a isso, a falta de acompanhamento e um manejo adequado do sistema vem proporcionando irrigações de baixa uniformidade e eficiência. Este trabalho visou desenvolver e testar um equipamento que seja capaz de avaliar o sistema de irrigação do produtor, tendo como parâmetros a lâmina média, e uniformidade de aplicação, de forma automática e simples. Testaram-se alguns sensores capazes de fazer leituras de nível d’água. Com o sensor definido foi construído o coletor de forma a levantar os dados para avaliação do sistema. Foram comparados os resultados obtidos com o sensor aos obtidos medindo o volume contido no coletor com auxílio da proveta graduada, sendo estes submetidos a testes estatísticos de comparação de médias. O dispositivo mostrou-se adequado para uso em condições de campo apresentando melhores resultados para lâminas maiores. O microcontrolador foi de fácil programação e manuseio, tendo resultados amplamente favoráveis a avaliação sistemática do sistema de irrigação.
Downloads
Referências
Faria, L. C.; Beskow, S.; Colombo, A.; Oliveira, H. F. E. 2012. Modelagem dos efeitos do vento na uniformidade da irrigação por aspersão: Aspersores de tamanho médio. Revista Brasileira de Engenharia Agrícola e Ambiental 16: 133-141. Doi: http://dx.doi.org/10.1590/S1415-43662012000200002.
Faria, L. C.; Beskow, S.; Colombo, A.; Nörenberg, B. G., Neto, O. R.; Simões, M. C. 2016. Influence of the wind on water application uniformity of a mechanical lateral move irrigation equipment using rotating plate sprinklers. Ciência Rural 46: 83-88. Doi: http://dx.doi.org/10.1590/0103-8478cr20141558.
Keller, J.; Karmeli, D. 1975. Trickle irrigation design. Rain Bird Sprinkler, Glendora, California, USA.
Mantovani, E. C.; Bernardo, S.; Palaretti, L. F. 2007. Irrigação: princípios e métodos. 2. ed. atualizada e ampliada. UFV, Viçosa, MG, Brasil.
Moraes, M. J.; Oliveira Filho, D.; Mantovani, E. C.; Monteiro, P. M. B.; Mendes, André L. C.; Damião, J. H. A. C. 2014. Automação em sistema de irrigação tipo pivô central para economia de energia elétrica. Engenharia Agrícola 34: 075-1088. Doi: http://dx.doi.org/10.1590/S0100-69162014000600005.
Moreira, J. A. A.; Cardoso A. F.; Costa, L. L.; Rodrigues, M. S.; Peixoto, N.; Braz, L. T. 2012. Manejo da irrigação para otimização da produtividade e qualidade de frutos de tomateiro em sistema de plantio direto. Irriga 17: 408-417. Avaliable at: https://goo.gl/4na9i1.
Palaretti, L. F.; Mantovani, E. C.; Sediyama, G. 2011. Caracterização e diagnóstico de sistemas de irrigação e práticas de manejo de água na citricultura do norte do estado de São Paulo. Cadernos de Ciência & Tecnologia 28:531-551. Avaliable at: https://goo.gl/eH8mUV.
Palaretti, L. F.; Zanini, J. R.; Vecchiato, D. A.; Dalri, A. B.; Faria, R. T. 2016. Análise dos coeficientes de uniformidade de aplicação de microaspersores. Irriga, Edição Especial: 89-98. Doi: http://dx.doi.org/10.15809/irriga.2016v1n01p89-98.
Paulino, M. A. de O.; de Figueiredo, F. P.; Fernandes, R. C.; Maia, J. T. L. S.; Guilherme, D. de O.; Barbosa, F. S. 2009. Avaliação da uniformidade e eficiência de aplicação de água em sistemas de irrigação por aspersão convencional. Revista Brasileira de Agricultura Irrigada 3: 48-54. Avaliable at: https://goo.gl/8MGC2r.
Sousa, M. B. A.; Mantovani, E. C.; Silva, J. G. F.; Vicente, M. R.; Vieira, G. H. S.; Soares, A. A. 2011. Manejo da irrigação na cafeicultura irrigada por pivô central nas regiões norte do Espírito Santo e extremo sul da Bahia. Bioscience Journal 27: 581-590. Avaliable at: https://goo.gl/TToQRj.
Downloads
Publicado
Como Citar
Edição
Seção
Licença
Autores que publicam nesta revista concordam com os seguintes termos:
Os Direitos Autorais para artigos publicados nesta revista são de direito do autor. Em virtude da aparecerem nesta revista de acesso público, os artigos são de uso gratuito, com atribuições próprias, em aplicações educacionais e não-comerciais.
A revista se reserva o direito de efetuar, nos originais, alterações de ordem normativa, ortográfica e gramatical, com vistas a manter o padrão culto da língua e a credibilidade do veículo. Respeitará, no entanto, o estilo de escrever dos autores.
Alterações, correções ou sugestões de ordem conceitual serão encaminhadas aos autores, quando necessário. Nesses casos, os artigos, depois de adequados, deverão ser submetidos a nova apreciação.
As opiniões emitidas pelos autores dos artigos são de sua exclusiva responsabilidade.